OpticalLinkTransmitter.GetSignalPowerFromAveragePower(Variable) Method

Top 

Description

Uses the ModulationType property of OpticalReceiver to compute the signal power for a given average power in watts.

 

Timing Precision Mode

This page describes functionality in nanosecond timing precision mode.

Click here to see the documentation for this object in millisecond timing precision mode.

 

Method Signature

OpticalLinkTransmitter.GetSignalPowerFromAveragePower(

Variable averagePower)

 

 

Arguments

averagePower


Description:

Average power consumed by the transmitter.

Units:

W

Valid Range:

averagePower > 0

 

 

 

Return Value

Type:

number

Units:

W

 

 

The value of the calculated signal power.

 

Syntax

myVariable1 = myOpticalLinkTransmitter1.GetSignalPowerFromAveragePower(myVariable2);

 

 

See also

OpticalLinkTransmitter Object